Power supply for terminal points is a common bottleneck during renovation in workshops and old buildings. End devices need data connectivity, yet no local power outlet is available nearby. The standard architecture splits the link into two segments: standard optical fiber runs from the equipment room to workshops or floors, while only the short terminal segment adopts POF optoelectronic composite cable. An optical socket serves as the transition point. Fiber carries data, and the embedded copper conductors deliver power, eliminating separate AC power wiring. For old buildings, cables are routed inside existing trays and conduits, with legacy copper cables reserved as rollback backup links.
Standard fiber for backbone runs, POF only for terminals — the full link is not a single composite cable.
The AINOPOL IP-POL Boundary-Free Solution divides the transmission path clearly. Standard optical fiber is deployed from the core equipment room to floor / workshop weak-current cabinets. It transmits purely optical signals with no conductive medium, immune to EMI from welding machines and motors even when crossing high electromagnetic areas. Only the short section from the weak-current cabinet optical socket to wall terminals uses POF optoelectronic composite cable, delivering both data and power in one cable.
This separation brings practical benefits. Standard fiber backbone supports long-distance transmission with tidy routing. The short terminal segment needs power supply for optical APs, which is perfectly handled by POF composite cable.
Optical sockets sit at the backbone termination point, converting optical signals and distributing power over POF to endpoints.
Optical sockets are installed inside workshop or floor weak-current cabinets, exactly where backbone fibers terminate. They receive optical signals from standard fiber and forward them through POF composite cables to each terminal. Wi-Fi 6 optical APs at endpoints draw power directly from the POF cable. No independent AC outlet is required, enabling network deployment at dead-corner locations without power.

POF optoelectronic composite cable supports non-repeater power & data transmission over 800+ meters, sufficient for most workshop layouts from weak-current cabinets to remote corners. AINOPOL industrial-grade optical terminals and optical sockets adapt to harsh environments including oil contamination, dust and wide temperature fluctuations, far more robust than copper cables and RJ45 connectors, delivering near maintenance-free operation in workshops. Pre-terminated POF cables are plugged in on-site, no field fiber splicing required to cut construction workload. Optical signals are electrically isolated, so intermittent packet loss caused by electromagnetic interference is greatly reduced.
Route along existing trays and conduits; keep legacy copper cables as backup rollback links.
The biggest restriction for aged buildings and factory offices is decoration and cable tray limits. Property management often rejects wall demolition, and trays cannot be expanded for extra cabling, forcing exposed messy wiring for new points. POF and fiber are routed inside original conduits and trays, with no tray expansion or wall chiseling.
Do not remove old copper cables immediately. Legacy copper circuits are reserved as rollback paths. Old and new networks run in parallel, with cutover executed floor by floor or department by department. Legacy cables and devices remain online until acceptance. Engineers can revert to the original link instantly if issues emerge after switching, and rollback procedures are documented formally. The reusable segments and available tray capacity are confirmed via link-by-link optical testing and site survey. All final arrangements follow the project design.
Fiber plus POF delivers one-stop deployment for workshops. Zonal phased migration keeps normal production during maintenance windows.
Pure copper cabling in workshops has obvious drawbacks: limited transmission distance, vulnerability to moisture and oxidation, and intermittent faults triggered by electromagnetic interference which are hard to diagnose with ordinary cable testers. After upgrading to fiber backbone plus POF terminals, the link is anti-interference, and endpoints receive power without extra AC circuits. Cutover is arranged by zone and time slot during maintenance periods, so daytime production stays uninterrupted. Each terminal AP connects via one POF cable: data over fiber, device power over built-in copper.
To summarize: standard fiber runs from equipment room to workshop weak-current cabinets, POF composite cable is only used for the terminal segment, and optical sockets act as the transition node for optical signal forwarding and remote power delivery. Deployment in old buildings leverages existing cable trays and conduits, with old copper reserved for rollback, no wall breaking and no full shutdown. AINOPOL supplies the full set including optical sockets, industrial terminals, optoelectronic APs and passive splitters. The final deployment plan is subject to on-site survey.
Q: What is the difference between POF composite cable and ordinary fiber?
A: Ordinary fiber only transmits data without power delivery, suited for long backbone runs from equipment room to weak-current rooms. POF optoelectronic composite cable carries both data and power in one cable, exclusively for short runs from optical sockets to terminals, powering optical APs and MDUs locally.
Q: What is the maximum transmission distance of POF?
A: It supports non-repeater transmission over 800 meters, which covers most intra-floor and workshop layouts. The splitting ratio and optical power budget require link-by-link verification, subject to site survey and project scheme.
Q: How to add network points in old buildings without local power outlets?
A: Deploy POF optoelectronic composite cable from optical sockets to supply power together with optical signals. Terminals like optoelectronic APs do not need separate AC wiring. Backbone fiber is routed along existing trays and conduits, with no wall breaking or tray expansion.