When renovating old buildings into all-optical networks, the biggest concerns are wall demolition, business suspension and repeated cabling. The renovation plan depends on equipment ownership and the cable type buried inside walls — fiber, Ethernet cable or POF. Based on equipment ownership and cable combinations, existing buildings fall into seven typical categories: carrier four-in-one fiber access, FTTB to floors, leased FTTR-B, self-built triple-network upgrade, self-built triple-network expansion, office zones in over-10-year-old buildings, and high-EMI workshops. What to retain, replace and add for each scenario is sorted clearly below.
Equipment ownership and cable types jointly decide what to keep, swap and deploy for each building.
If the equipment belongs to the carrier or is still under lease, most intermediate cables can be reused; only core-side and terminal hardware are replaced. If the network is self-built and existing services run stably, new optical branches are deployed only for new floors or new zones. Judgement starts from two points: who owns the equipment and what cables are routed inside walls, followed by link-by-link verification on site.
The AINOPOL IP-POL Boundary-Free Solution follows this principle: reuse usable old cables and replace only necessary hardware. It supports reuse of existing Ethernet cables, incoming fibers, POF cables and legacy data communication devices. A converged gateway or OLT is deployed in the equipment room, passive splitters or optical sockets are installed on floors, and one optoelectronic AP per room delivers internet, IPTV and voice services together. Traditional switches can coexist with the POL architecture and be replaced floor by floor. What customers truly need is not just the label "all-optical network", but renovation without wall breaking, zero service shutdown and full independent control afterwards.
Differences among the seven scenarios focus on three actions: retain, replace and add.
表格
| Scenario | What to Retain | What to Replace | What to Add |
|---|---|---|---|
| Carrier four-in-one fiber access | Incoming fiber, building backbone, decoration | Carrier splitters, four-in-one terminals | Self-built converged gateway, passive splitters, room optoelectronic APs |
| FTTB to floors | Incoming fiber, floor-to-room fiber, fiber routing and connectors | Floor MDUs, legacy room terminals | Self-built core equipment, room optoelectronic APs |
| Self-built triple-network functional upgrade | Survey-verified usable Ethernet cables, existing services | Legacy AC controllers, old APs, aged end terminals | Fiber trunk from core room to floors, vOLT, in-room fiber and optoelectronic APs |
| Self-built triple-network expansion | Original cables, existing PBX | Keep legacy system, only replace faulty units | O-port gateway for PBX interconnection, vOLT, new PON branches, optoelectronic APs for new rooms |
| Leased FTTR-B (POF) | POF trunk & branch cables, drop wiring | Leased master gateway, original optoelectronic terminals | Self-built core gateway, proprietary optoelectronic APs |
| High electromagnetic interference workshop | Core equipment, machine-room-side cables | Copper drop cables inside workshop | Optical trunk from equipment room to workshop, optical sockets, POF optoelectronic composite cables |
| Office zone in over-10-year-old buildings | Core equipment, backbone fiber, usable cable trays & conduits | Old copper cables from weak-current cabinets to workstations | Optical sockets or vOLT modules for floor switches, end-side optoelectronic composite cables |
This table is for conceptual reference only. The final plan is subject to site survey and project design. One single building may fit more than one scenario. All arrangements revolve around retain, replace and add.
The "only swap two ends" approach has clear boundaries. The two ends refer to the core-side converged gateway, plus floor splitters, MDUs and room optoelectronic APs. The middle segments include incoming fiber, backbone fiber, POF and usable Ethernet cables validated by survey.

The "zero cable change" mode applies to four-in-one access, FTTB and leased FTTR-B. For self-built triple networks and old office buildings, new backbone or branch fiber will be routed along existing trays while old cables stay in service. For workshops, copper drops are replaced with optoelectronic composite cables. After migration, the hotel or campus gains full ownership and super-admin rights, with independent control over VLAN, port mapping and QoS.
Eight sets of information collected on-site determine the scope of reusable cabling and avoid repeated visits:
Engineers further verify optical power budget, optical power deviation among terminals under one PON port, splitting ratio, port density and cable aging condition link by link.
The topology drawings provided by AINOPOL illustrate the renovation scope for each scenario for reference only, and cannot serve as construction drawings. Uncertain conditions require an on-site survey first.
To upgrade old buildings to all-optical networks, identify equipment ownership and buried cable types, then match the scenario against the quick reference table and split works into retain / replace / add. Reuse cables wherever possible and replace only necessary hardware. The AINOPOL IP-POL Boundary-Free Solution delivers wall-free renovation and transfers asset ownership and management permissions back to the owner after completion.
Q: How do I confirm which scenario I belong to?
A: First clarify equipment ownership and the cable type in walls, then check the table. If all equipment belongs to the operator, it is most likely four-in-one fiber access or FTTB. Self-built three-service networks requiring function upgrades or room expansion correspond to triple-network upgrade and expansion cases. Book a site survey if you cannot tell.
Q: Do all seven scenarios require breaking walls?
A: Four-in-one access, FTTB and leased FTTR-B reuse all incoming fiber and POF without recabling. For self-built triple networks and old office buildings, new trunks or branches are laid along existing trays while old cables remain. For EMI workshops and aged offices, only copper drops are converted to fiber. No large-scale decoration damage will happen, while optical parameters must be validated link by link.