For hotels adopting FTTB (Fiber To The Building) deployment, carrier MDUs are installed in floor telecommunication closets, with in-room optical fibers already routed to all guest rooms. The core of this type of legacy renovation is to distinguish between floor segments and in-room segments: replace the carrier MDU in place with hotel-owned hardware while keeping all existing in-room fiber cables untouched. This approach avoids recabling, and transfers equipment ownership and management privileges back to the hotel. The feasibility of in-situ replacement depends on existing fiber quality and cable tray conditions, subject to on-site survey and project design.
The difference between FTTB and FTTH lies in where the optical fiber terminates, and this boundary determines which parts will be modified during renovation.
FTTH (Fiber To The Home): Optical fibers run straight into each guest room, with an optical terminal deployed inside the room to deliver internet, TV and voice services. The service boundary is inside the guest room.
FTTB (Fiber To The Building): Backbone fibers only reach floor telecommunication closets and terminate at the floor MDU. Separate fiber links extend from this MDU to individual guest rooms. The service boundary is the MDU inside the telecommunication closet.
Renovation workflows differ according to this boundary. FTTH projects mainly replace room terminals and central office equipment. FTTB has an extra layer, requiring takeover of the floor MDU first. Since this MDU belongs to the carrier, the hotel cannot adjust internal configurations. VLAN settings, SSIDs and TV launcher customization are inaccessible, and fault resolution relies on carrier on-site support.
When floor equipment is carrier-owned and fibers are already laid to rooms, this falls into the "retain all cables, only replace end devices" model: swap out the floor box and room terminals for self-owned hardware while keeping existing in-room fibers.
In-situ replacement means substituting the carrier MDU with self-owned equipment, preserving all fiber connectors and routing paths.

Renovation follows this sequence: In-situ MDU replacement → Optoelectronic AP deployment in rooms → Self-built central office.
Remove the original carrier MDU from its mounting position and install AINOPOL ONU in the same spot. Reconnect the existing pigtails in the original order. Fiber joints and routing remain unchanged, no wall demolition, no new cabling or tray modification. All in-room and floor-to-room fibers are fully reused. The new AINOPOL unit terminates uplink backbone traffic and distributes services to rooms on the floor, replacing the original carrier-controlled device and handing full configuration rights back to the hotel.
In-situ replacement cannot proceed without pre-verification. Technicians must check optical receiving power range, optical power difference across terminals under one PON port, splitting ratio, port density and cable aging condition link by link on site. The scope of reusable cabling is subject to on-site survey and project plans. Legacy devices and cables stay in place until project acceptance. Cutover is executed in batches. If any guest room encounters abnormal service, roll back to the original link immediately, with formal rollback procedures documented in implementation files.
A single optoelectronic AP converges all three types of services inside guest rooms.
Legacy multi-function terminals in guest rooms are replaced by optoelectronic APs, consolidating internet, IPTV and voice access. Multiple set-top boxes are no longer required in guest rooms. Customizable TV launcher and screen casting are supported, merging two remote controllers into one. Voice service runs locally, so in-room intercom remains available even when external internet drops.
Real-name authentication and log retention for public Wi-Fi are implemented simultaneously via the Mengxiang Gateway on-premises. It supports one account per guest bound to room number, with logs stored locally in rolling mode for a minimum of 180 days. Complete log fields can be exported filtered by room ID. Guest Wi-Fi and internal hotel network are isolated via VLAN, and compliance reports can be generated directly from the management backend.
Building a self-managed central office transfers both equipment ownership and configuration authority to the hotel.
A Mengxiang Gateway is deployed in the core computer room, integrating OLT optical access, AC wireless controller, IPPBX voice module, firewall and guest authentication functions into one appliance, drastically reducing the total number of rack-mounted devices. The hotel independently applies for outbound bandwidth, gaining full ownership of bandwidth and network hardware.
The most practical benefit after deployment is full controllability. VLAN division, port mapping and QoS tuning can be adjusted directly in the backend without service tickets or waiting for carrier technicians. Surveillance and access control systems support native integration. Future bandwidth upgrades are straightforward thanks to the decoupled optical foundation and end devices. Upgrades from GPON to XGS-PON, 50G PON and Wi-Fi 7 optical APs only require replacement of end-side hardware, leaving intermediate fibers and splitters untouched.
For FTTB renovation, the key is to clarify the service boundary: if fibers terminate at the floor, the floor MDU must be taken over first. The AINOPOL MDU replaces the carrier unit in situ, optoelectronic APs are deployed in guest rooms, and the Mengxiang Gateway forms the self-managed central office. Following this workflow, all in-room fiber cables stay intact, and the hotel recovers equipment ownership and configuration permissions. The scope of reusable cables and optical splitting scheme are finalized based on on-site survey.
Q: What is the difference between FTTB and FTTH renovation?
A: For FTTH, fibers extend into guest rooms, and only room terminals and central office hardware are replaced. For FTTB, fibers only reach floor weak-current rooms, with an additional floor MDU to be migrated. The boundary of FTTH is inside guest rooms while FTTB’s boundary is the floor telecommunication closet, so FTTB requires the extra step of MDU in-situ replacement.
Q: Do cables need to be modified after replacing the floor box?
A: All in-room fibers and floor-to-room fibers are retained, connectors and routing stay the same with no new cabling. Only the floor MDU and room terminals are swapped, alongside a new self-built central office. Link-by-link verification via site survey is still required to confirm reusable segments.
Q: Can the existing TV sets keep working?
A: TV service is delivered by the room optoelectronic AP, which supports customized launcher and screen casting, merging two remote controls. The Mengxiang Gateway in the computer room provides local voice and internet service, and in-room phones still work when external internet is disconnected.