On a Wednesday morning solution meeting, project manager Lao Zhou from the property owner laid two diagrams side by side on the table. On the left was the traditional Ethernet currently deployed in the building, and on the right was the all-optical network topology submitted by the system integrator. He stared at them for a long time: both use optical fibers, so why does the right side have one fewer cabinet?
The building where Lao Zhou works has been in use for more than ten years, adopting a three-layer architecture: core — aggregation — access. The core switch sits in the computer room, with aggregation switches in the weak-current room on each floor, before connecting to rooms. All three layers consist of active devices, which require power supply and heat dissipation in weak-current rooms. He just submitted a repair request last month for a cabinet whose fan on this layer had failed.
The right side shows the flattened two-layer structure of POL: from the central office terminal, signals pass through a passive optical splitter in the middle, and terminate at optical-electrical APs in a point-to-multipoint topology. The aggregation layer is eliminated. The powered switch in the weak-current room is replaced by a small passive box that needs no power supply or heat dissipation and can fit inside a weak-current junction box.
A common confusion is "Ethernet All-Optical". It only replaces copper cables with optical fibers while retaining the original three-layer architecture, and the active aggregation switches in weak-current rooms remain in place. What POL changes is not the cable material, but the intermediate layer of devices.
Lao Zhou’s biggest worry is wall demolition. The guest rooms have just been renovated; tearing open the ceiling will cost more for restoration than the equipment itself.

The AINOPOL IP-POL Boundary-Free Solution takes a different approach: it reuses existing network cables, home-entry optical fibers, POF optoelectronic composite cables and existing data communication equipment, replacing only the devices that need upgrading.
Traditional switches can coexist with POL, allowing phased replacement by floor or service type. The work is simplified to retaining, replacing and adding: keep usable optical cables, network cables and cable trays; replace operator terminals and aging splitters; supplement converged gateways and optical sockets.
Optical fibers transmit optical signals. The medium is non-conductive and immune to electromagnetic interference. Copper cables, by contrast, are prone to oxidation and moisture. Most network outages in old buildings caused by corroded crystal connectors stem from this. There is no need to replace the existing cabling segment if site survey confirms it is usable. Which lines can be retained shall be subject to on-site survey and project plans.
Another change shown in the right diagram: office network, surveillance, voice, video conferencing and Wi-Fi all run on the same optical fiber network, separated by VLAN isolation, instead of deploying a dedicated cabling system for each service. Lao Zhou once counted the equipment in his computer room rack: separate sets for internet access, telephone and surveillance, and the drawings no longer match the actual setup.
The network is converged by the Mengxiang Gateway: it integrates optical access, wireless controller, voice module, firewall and guest authentication into one appliance, drastically cutting down the number of devices in the computer room. Link protection is supported, with millisecond-level failover upon faults. After deployment, the equipment ownership and super administrator access rights are handed back to the property owner. VLAN division and port mapping can be configured independently, and surveillance & access control docking does not require work orders.
Whether rewiring is needed for old buildings depends first on equipment ownership and concealed cabling, then the survey conclusion. The three-layer architecture evolves into a flattened two-layer design with passive weak-current rooms. Multiple services run on one network isolated by VLAN, and the Mengxiang Gateway converges all services in the computer room. The core of the AINOPOL IP-POL Boundary-Free Solution is: retain usable old cables, replace only necessary equipment.
Q: What is the difference between an all-optical network and Ethernet all-optical network?
A: Ethernet all-optical only replaces copper cables with optical fibers and keeps the three-layer architecture. POL replaces the intermediate aggregation layer with passive splitters, adopting a flattened point-to-multipoint two-layer topology. Weak-current rooms require no power supply or heat dissipation.
Q: Do weak-current rooms still need power supply and air conditioning after switching to POL?
A: Splitters need no power or heat dissipation. They can be installed inside weak-current boxes or wall-mounted. The power supply and air conditioning originally configured for aggregation cabinets are no longer required for these devices. Specific installation points shall follow on-site survey and project plans.
Q: Can old buildings deploy all-optical networks without recabling?
A: If the equipment belongs to operators and concealed cables are home-entry optical fibers or pre-laid POF cables, only end devices need replacement. For self-built legacy three-network systems with copper cable terminals, new backbone cables or end optoelectronic composite cables are required, while old cables can be retained until acceptance. The scope of retained cabling is subject to on-site survey and project plans.